Instruction Manual

Piezoelectric proximity mode sensors with push-button programming of sensing window limits
Ultrasonic proximity detection from 0.25 to 3.0 m (9.8 to 118 inches)
Push-button TEACH-mode programming of sensing window limits
Digital filtering for exceptional immunity to electrical and acoustic “noise”
Selectable 0 to 10V dc voltage sourcing or 4 to 20 mA current sourcing analog out-
puts
Selectable output slope: positive or negative with increasing target distance
Wide operating temperature range of –25 to +70 °C; all models include tempera-
ture compensation
Rugged design for use in demanding sensing environments; rated IEC IP67,
NEMA 6P
Choose models with integral 2 m (6.5 ft) or 9 m (30 ft) cable, or with Mini-style or
Euro-style quick-disconnect fitting
Input for remote TEACH-mode programming of window limits
Models
Temperature
Compensation
Cable Supply Voltage Output Type Response Time
Q45ULIU64BCR
Yes
2 m (6.5 ft)
15–24V dc
Selectable 0–10V dc or 4–
20 mA sourcing
Adjustable from 80
milliseconds to 2.56
seconds
Q45ULIU64BCRQ 5-Pin Mini-style QD
Q45ULIU64BCRQ6 5-Pin Euro-style QD
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. For
example, Q45ULIU64BCR W/30. Models with a QD connector require a mating cable.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Temperature Compensation
All models listed above feature temperature compensation. An increase in air temperature shifts both sensing window limits closer to the
sensor. Conversely, a decrease in air temperature shifts both limits further away from the sensor. The shift is approximately 3.5% of the
limit distance for a 20 °C change in temperature.
Temperature compensated models maintain the position of both sensing window limits to within 1% of each limit distance over the 0 to
+50 °C range, and to within 2.5% over the full operating range of from –25 to +70 °C.
Setting the Near and Far Sensing Limits
The Q45U features a single push button for programming of sensing window near and far limits. For more information, refer to Program-
ming the Window Limits on page 4.
Status Indicators
Status indicator LEDs are visible through the transparent, o-ring sealed acrylic top cover. Indicator function in the Run mode is, as fol-
lows:
Q45U Ultrasonic Sensors with Analog Outputs (Long Range)
P/N 48456 Rev. E 8/21/2013

Summary of content (9 pages)