Owner manual

P/N 137526 rev. A 3
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
SureCross™ DX80 FlexPower™ Node for EZ-LIGHT™
Device Configuration
Address Mode
In Rotary Switch address mode, the left rotary dial establishes
the network ID and the right rotary dial sets the device ID. The
wireless network is restricted to a maximum of 16 devices.
Extended addressing mode allows for specific Node to Gateway
binding and allows network expansion for more than 16 devices
in a wireless network. For most users, this switch is OFF.
For more information on extended address mode, refer to the
SureCross™ Wireless I/O Network product manual.
Configuration
The factory default configurations are outlined in the device data sheet. Turning DIP switch 2 to the ON position enables the DIP switches 3
through 8. Use DIP switch 3 to enable or disable configuration from external sources, including host systems and special Gateways.
LED Current Level
Selecting the current levels 1 through 4 control the brightness of the K50 light. Level 1 is the dimmest setting, typically used for indoor
applications or to extend battery life. Level 4 is the brightest setting, typically used for outdoor applications.
Duty Cycle
The duty cycle settings refer to how long the light is on during each second duty cycle. For example, selecting 1/16 LED Duty Cycle turns the
K50 EZ-LIGHT ON for 1/16th of each second and OFF for the remaining 15/16th of each second.
Switches
Device Settings 1 2 3 4 5 6 7 8
Rotary Switch Address Mode OFF*
DX80 Extended Address Mode ON
Factory Default Configuration OFF*
Enable DIP Switch Configuration ON
Disable External Configuration OFF*
Allow External Configuration ON
LED Current Level (Brightness) 1 OFF* OFF*
LED Current Level (Brightness) 2 OFF ON
LED Current Level (Brightness) 3 ON OFF
LED Current Level (Brightness) 4 ON ON
Reserved OFF* OFF* OFF*
1/16 LED Duty Cycle OFF OFF ON
1/8 LED Duty Cycle OFF ON OFF
3/16 LED Duty Cycle OFF ON ON
1/4 LED Duty Cycle ON OFF OFF
3/8 LED Duty Cycle ON OFF ON
1/2 LED Duty Cycle ON ON OFF
Continuous ON ON ON
* Default configuration