Manual

WARNING: Not a Safeguarding Device
An Emergency Stop Device is not considered a safeguarding device because it requires an
overt action by an individual to stop machine motion or hazards.
A safeguarding device limits or eliminates an individual's exposure to a hazard without action by the
individual or others. Because an individual must actuate the device for it to function, these devices do
not fit the definition of a safeguarding device and cannot be substituted for required safeguarding. Refer
to the relevant standards to determine those requirements.
WARNING: Emergency Stop Functions
Do not mute or bypass any Emergency Stop device. ANSI B11.19, ANSI NFPA79 and IEC/EN
60204-1 require that the Emergency Stop function remain active at all times.
Green
Figure 1. Run Condition (Proper Rope Tension) - Contacts 11/12 Closed
Yellow
Figure 2. Rope Pulled Condition - Contacts 11/12 Open
Yellow
Figure 3. Rope Break Condition - Contacts 11/12 Open
Mechanical Installation
The rope should be easily accessible and visible along its entire length. Markers or flags may be fixed on the rope
to increase its visibility
Switch body, anchor mounts and wire rope supports (pulleys or eye bolts) must be rigid and secure
Although pulleys are preferred, a combination of pulleys and/or eye bolts are required to support the wire rope
along its length. When pulled, the wire rope, should move freely through the pulleys or eye bolts to actuate the
switch
Use only pulleys (not eye bolts) when routing the rope around a corner or whenever direction changes, even
slightly
Never run rope through conduit or other tubing
Never attach weights to the rope
Temperature affects rope tension. The rope expands (lengthens) when temperature increases, and contracts
(shrinks) when temperature decreases. Significant temperature variations require frequent checks of the tension
adjustment
Do not exceed the maximum specified total rope length. Banner offers models for other spans; contact Banner
Engineering or visit www.bannerengineering.com for model selection
RP-RM83F Heavy-Duty Rope Pull Emergency Stop Switches
P/N 141245 Rev. C www.bannerengineering.com - tel: 763-544-3164 3