Instruction Manual

Repair any loose or damaged hardware, worn/frayed rope (cable), missing red rope sheathing or flags/markers (if
used)
Remove or clean off any contamination and eliminate its cause
Repairs
Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it
contains no field-replaceable components. If the device or a device component is determined to be defective by a
Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure.
Important: If instructed to return the device, pack it with care. Damage that occurs in return shipping
is not covered by warranty.
Specifications
Contact Rating
10 A at 24 V ac
10 A at 110 V ac
6 A at 230 V ac
6 A at 24V dc
2.5 kV max. transient tolerance
NEMA A300 P300
European Rating
Utilization categories: AC15 and DC13
Switches with 1 and 2 contact pairs: Ui = 500V ac; Ith
= 10A
40-60 Hz
Ue (A) Ie/AC-15 (A) Ie/DC-13 (A)
24 10 6
110 10 1
230 6 0.4
Contact Material
Silver-nickel allow
Maximum Switching Speed
50 operations per minute
Recommended Rope Size
2 mm diameter steel rope
Maximum Rope Pull Length
6 m (20 ft)
Short Circuit Protection
10 amp Slow Blow, 15 amp Fast Blow. Recommended
external fusing or overload protection.
Mechanical Life
1 million operations
Wire Connections
Screw terminals with pressure plates accept the
following wire sizes –
Stranded and solid: 20 AWG (0.5 mm
2
) to 16 AWG
(1.5 mm
2
) for one wire
Stranded: 20 AWG (0.5 mm
2
) to 18 AWG (1.0 mm
2
)
for two wires
Cable Entry
M20 x 1.5 threaded entrance. Adapter supplied to
convert M20 x 1.5 to ½"-14 NPT threaded entrance
Construction
Aluminum alloy die-cast
Environmental Rating
IEC IP65
Operating Conditions
Temperature: –30 to 80 °C (–22 to 176 °F)
Weight
RP-LM40D-6: 0.22 Kg (0.49 lbs)
RP-LM40D-6L: 0.26 Kg (0.57 lbs)
Certifications
RP-LM40 Series Rope Pull Switches
P/N 62082 Rev. C www.bannerengineering.com - tel: 763-544-3164 5