Owner manual
P/N 114348
      9
Q60LAF Series Laser Adjustable-Field Sensors
Banner Engineering Corp. 
• 
Minneapolis MN, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Specifications
Supply Voltage and 
Current
Q60BB6LAF models: 
10 to 30V dc (10% maximum ripple) at less than 35 mA exclusive of load
Q60VR3LAF Universal models: 
12 to 250V dc or 24 to 250V ac, 50/60 Hz
Input power 1.5 W maximum 
Supply Protection 
Protected against reverse polarity and transient voltages
(Q60VR3 models’ dc hookup is without regard to polarity)
Output Configuration
Q60BB6LAF models:
 Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector 
transistor
Q60VR3LAF cabled model:
 E/M Relay (SPDT), normally closed and normally open contacts
Q60VR3LAFQ1 (QD) model:
 E/M Relay (SPST), normally open contact
Output Rating
Q60BB6LAF models
Q60BB6LAF models
150 mA maximum each output @ 25° C
Off-state leakage current:
 < 5µA @ 30V dc  
Output sat u ra tion NPN:  
< 200 mV @ 10 mA and < 1V @150mA
Output sat u ra tion PNP:
 < 1V at 10 mA; < 1.5V at 150 mA
Q60VR3LAF Universal models
Q60VR3LAF Universal models
Min. voltage and current:
 5V dc, 10 mA
Mechanical life of relay:
 50,000,000 operations
Electrical life of relay at full resistive load:
 100,000 operations
Max. switching power (resistive load):
Cabled models:
 1250VA, 150 W
QD models:
 750VA, 90W
Max. switching voltage (resistive load):
Cabled models:
 250V ac, 125V dc
QD models: 
250V ac, 125V dc
Max. switching current (resistive load):
Cabled models: 
5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
QD models:
 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc
Output Protection 
Circuitry
Q60BB6LAF models:
 Protected against continuous overload or short circuit of outputs
All models:
 Protected against false pulse on power-up
NOTE: 1 second max. delay at power up (outputs do not conduct during this time).
Output Response Time
Q60BB6LAF models:
 2 milliseconds ON and OFF
Q60VR3LAF Universal models:
 15 milliseconds ON and OFF
Repeatability
500 microseconds
Sensing Hysteresis
See Figure 4.
Indicators (see Figure 1)
NOTE:   Outputs are 
active during 
on/off timing 
selection mode.
ON-Delay
ON Green:
 RUN mode, ON-delay active
Flashing Green:
 ON-Delay Selection mode
OFF-Delay
ON Green:
 RUN mode, OFF-delay active
Flashing Green: 
OFF-Delay Selection mode
5-Segment Light Bar*
ON/OFF-Delay Selection: 
Indicates relative delay time
RUN Mode:
Output
ON Yellow:
 Outputs are conducting
ON Green:
 ON/OFF-Delay Selection
Dark Operate
ON Green:
 Dark Operate selected
Lockout
ON Green:
 Buttons locked out
Light Operate
ON Green:
 Light Operate selected
Signal
ON Green: 
Sensor receiving signal
Flashing Green:
 Marginal signal (1.0 to 2.25 excess gain)
Laser Characteristics
Spot Size:
 approximately 4 x 2 mm throughout range (collimated beam)
Angle of Divergence:
 5 milliradians
NOTE: Contact factory for custom laser spot size.