Manual

Q60AF Sensors
Long-Range Self-Contained Adjustable-Field Sensors
Printed in USA 06/02 P/N 67003 rev. B
Q60AF Adjustable-Field Features
Long-range adjustable-field background suppression sensor detects objects within a defined
sensing field, while ignoring objects located beyond the sensing field cutoff
•Two-turn, logarithmic adjustment of sensing field cutoff point from 0.2 to 2 m; allows easy
setting of cutoff point at long range
Rotating pointer indicates relative cutoff point setting
Easy push-button or remote programming of light/dark operate and output timing;
continuous status indicators verify all settings at a glance
Output ON and/or OFF delays adjustable from 8 milliseconds to 16 seconds
Powerful infrared sensing beam
•Tough ABS/polycarbonate blend housing is rated IEC IP67; NEMA 6
10-30V dc Models (Q60BB6AF):
Powered by 10 to 30V dc; bipolar (one NPN and one PNP) outputs
•Available with integral cable or rotating Euro-style quick-disconnect fitting
Universal Voltage Models (Q60VR3AF):
12-250V dc or 24-250V ac, 50/60 Hz
•Available with integral cable or rotating Micro-style quick-disconnect fitting
Infrared, 880 nm
Q60 Adjustable-Field Models
* 9 meter cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., Q60BB6AF2000 W/30).
A model with a QD connector requires a mating cable; see page 8.
Q60BB6AF2000
50 mm
to 125 mm
(2" to 5")
depending
on cutoff
point setting
5-wire
2 m (6.5')
10-30V dc
Bipolar
NPN/PNP
1
10
100
.10 m
.33 ft
1.0 m
3.3 ft
10 m
33 ft
.01 m
.033 ft
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
10000
Q60AF
Models
Minimum
Range Cable*
Supply
Voltage
Output
Type
Excess Gain at
200 mm Cutoff
Adjustable:
200 mm to
2000 mm
(8" to 80")
Cutoff
Point
1
10
100
.10 m
.33 ft
1.0 m
3.3 ft
10 m
33 ft
.01 m
.033 ft
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
10000
Q60AF
Excess Gain at
2000 mm Cutoff
Q60BB6AF2000Q
5-pin
Euro-style
QD
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or
malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety
products which meet OSHA, ANSI and IEC standards for personnel protection.
!
Q60VR3AF2000
5-wire
2 m (6.5')
Universal
Voltage
12-250V dc
or
24-250V ac
E/M Relay
(SPDT),
normally
closed and
normally open
contacts
Q60VR3AF2000Q1
4-pin
Micro-style
QD
E/M Relay
(SPST),
normally
open
contact

Summary of content (8 pages)