Owner's manual

STP25 — 7.6 m (25') DB9P30 — 9 m (30')
*The Sensor can be connected to the PC via a serial cable or an Ethernet network; Ethernet provides faster
communication.
DirectionDescriptionWire ColorPin #
OutputRS-232 TX**Yellow1
InputRemote TeachGray2
InputProduct ChangeOrange3
InputExternal TriggerPink4
In/OutDiscrete I/O #1Black5
In/OutDiscrete I/O #2Red6
In/OutDiscrete I/O #3White7
In/OutDiscrete I/O #4Light Blue8
InputRS-232 RX**Violet9
OutputRS-232 Signal Ground**Green10
InputCommon (Signal Ground)Blue11
Input10-30V dcBrown12
** These three wires make up the RS-232 serial connection.
Note: All unused inputs and outputs should be connected to ground if configured as PNP, and
connected to +24V dc if configured as NPN. Serial input pins should be connected to ground.
2.2 Software Overview
The PresencePLUS application window is shown below.
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
12