Owner manual

DescriptionStrobe Width Option
The strobe output remains active (light on).On
The strobe output is active only while the sensor is
acquiring an image. This is the default.
Exposure Duration
Sets the duration for active strobe output from the initial
valid trigger (minimum pulse width has been satised) to
the end of the duration. The range is from 0 to 4,000 ms.
Time Duration
6.4.2 Level
Active Low -- When given a 0V dc signal, it turns on. This is the default.
Active High -- When given a +5V dc signal, it turns on.
6.5 Units Tab
By default, the sensor expresses all distance calculations as pixels:
Congure a scale value based on a known distance in user-selected units (for example, inches, millimeters, or
centimeters) See Congure with Known Distance on page 84 for more information.
Units Tab
Banner Engineering Corp.Minneapolis, MN USA82
2/2010System Setup Dialog