Main Tasks to CompleteStep 3
2. Click the OK button to accept the conguration.
Kawasaki Protocol Defaults
The default Kawasaki protocol conguration parameters are:
Ethernet Socket 1 congured for TCP/IP Port 20000 as the communications channel
No Frame Start (Command Start) delimiter
Carriage Return/Line Feed as Frame End (Command End) delimiter
Space as the input command eld separator
Comma as the output eld separator.
Note: You can adjust each of these parameters as necessary, but corresponding
adjustments will have to be made to the sample AS Language program provided to
enable successful communication.
Creating the PresencePLUS Inspection
Main Tasks to CompleteStep 1
Enable the Coordinate
Tool in the Tool
Conguration dialog.
1. Click the System button in the upper-right corner of the PresencePLUS GUI.
2. Select the Tools Conguration tab.
65Minneapolis, MN USABanner Engineering Corp.
System Setup Dialog2/2010