Because there is no ow control for the serial connections, the sensor wil not detect or log a lost or broken
connection
Industrial Ethernet
Protocol
Protocol selects which Industrial Ethernet protocol is being used. This changes the string format and the word/register
values reported in the PLC Map.
32 bit Format
32 bit Format determines how 32 bit integers and oating point values are stored in sequential 16 bit registers (words)
- least signicant word rst (LSW-MSW) or most signicant word rst (MSW-LSW).
Character String Order
For Modbus/TCP and PCCC protocols, characters in the string can be packed into registers according to either the
Standard String format or the ControlLogix Format1:
Standard String Format is used when the Character String Order option is set to High Byte Low Byte selection.
Please note that the length of the string is stored in one 16-bit register:
ControlLogix packing format is used to store characters into registers when the Character String Order option is set
to Low Byte High Byte selection.
Please note that in this particular case, the length of the string is still stored in one 16-bit register, and only
the order of characters in each 16-bit register follows the ControlLogix format: