5.4.2 Inspection Storage Capacity
The INS le format allows for the storage of inspection les onboard every sensor. The table below shows the storage
capacity for the various Vision sensors. Stored inspections can be modied, run, or deleted on the sensor.
Number of INS les
without Reference Images*
Number of INS FilesINS Storage MemorySensor Type
99918864MBPro II
99916064MBPro II Color
500+1508MBArea/GEO/Edge
9998532MBOMNI
9997232MBOMNI Color
9994464MBPro II 1.3
9994464MBOMNI 1.3
400+8BCR
9992032GEO/Edge/Area/BCR 1.3
*Not saving a reference image with the inspection frees up a lot of room onboard the sensor. However, inspections
that include any of the following tools require a reference image to be saved:
Geometric Find
Geometric Count
Pattern Find
Pattern Count
Color Match
Color BLOB
5.4.3 Opening an Inspection from the Sensor or a Library
Inspections can be stored on the sensor or to a libary of inspections stored on a PC or network drive. To select and
open an inspection from the sensor or a library:
1. Click the Load tab.
2. From the Load from drop-down list, select the Sensor or a location on a PC or Network.
3. Select the desired inspection.
4. Click the Load button.
The tools from the selected inspection populate the Navigation/Results window. At this point, all tools in the inspection
can be modied. If new tools are to be added, simply select the tool in the Tool screen. If tools are to be deleted, select
the tool and click the Delete icon.
Note: If you want to see the the image stored with the inspection, check the Load reference image box.