Owner manual

CommentsOptional
Qualiers
Required
Qualiers
Support ActionsObject or
Activity
Identier
System Object,
Component, or
Activity
Enables frame
number as
NoneENABLESETFRAMETAGFrame Number
Tag
command
acceptance
indicator
Disables frame
number as
NoneDISABLESETFRAMETAGFrame Number
Tag
command
acceptance
indicator
Retrieve the status
of the frame tag
indicator
NoneNoneGETFRAMETAGFrame Number
Tag
8.7.2 RCC Return Values
RCC return values are numeric, and are listed below:
0 - command accepted. This return code is generated when a valid SET, GET, and EXEC command has been completely
handled by the sensor. It may be followed by a command-specic return value or a completion code.
If the frame tag is enabled, the current frame number will be returned instead of 0 as command acceptance indicator.
-100 - Invalid command entered by the user.
Trigger and Product Change error codes:
-201 - Product change command attempted in the middle of the inspection
-202 Trigger command attempted in the middle of product change
-203 Trigger command is attempted when the inspection is not executing (sensor is idle)
-204 Specied inspection slot is out of range
-205 Trigger command attempted in the middle of the inspection
-206 Product change command attempted in the middle of a product change
-207 Product change command attempted while the sensor is in the Teach mode
-208 Product change attempted when the GUI is connected, and the inspection is not executing
Comm tool error codes
-301 get/set tool command attempted while the inspection is not executing
-302 get command issued before inspection is triggered for the rst time tool results unavailable
-303 get/set tool command attempted in the middle of the inspection
-304 get/set tool command attempted in the middle of the product change
-305 Tool specied in get/set command not found in the inspection
-306 Requested comm tool is not congured for RCC
-307 - Tool executed with an error or did not execute
-308 - Specied tool operand is not a constant, and cannot be modied
Reset command error codes
-401 Reset command attempted in the middle of the inspection
-402 Reset command attempted in the middle of the product change
-500 RCC commands are not accepted because the sensor is in the Playback mode
Timeout error codes
Banner Engineering Corp.Minneapolis, MN USA324
2/2010Communication Tool Setup