Owner manual
4.4.1 Trigger Settings
DescriptionField
Sets the sequence of valid triggers. If set to 1, an image is captured in response to every
valid trigger; if set to 2, and image is captured in response to every second valid trigger,
and so on.
Trigger Divide (range:
1-10,000 triggers)
Fixed time (ms) from the instant the Sensor receives a valid trigger to the instant the
Sensor captures the image.
Trigger Delay (range:
0-8,000 ms)
Eliminates unwanted triggers by accepting triggers only if they are above a specified
duration.
Minimum Trigger Width
(range: 1-8,000 ms)
Choose Leading Edge to capture images at the leading edge of a trigger signal. Choose
Trailing Edge to capture images at the trailing edge of the trigger signal.
Polarity
4.4.2 Resolution
Increases or decreases the resolution on the displayed image. A lower resolution will have a faster PC update. The
resolution does not change the inspection. Resolution options are 1:1, 4:1, 16:1, and 64:1.