Owner manual

PortDefault IP AddressSocket
20,007192.168.0.18
20,008192.168.0.19
20,009192.168.0.110
The serial port is the RS-232 connector (Pins 1, 9, and 10) on the Sensor. The deafult settings for the serial port
are listed below.
Default SettingAttribute
115200Baud Rate
8Data Bits
NoneParity
1Stop Bit
NoneFlow Control
3. Format the ASCII string of data (in the Format eld).
Choose a Delimiter and Start and End strings.
Check the Enable Labels box to add the names for data being sent.
Allowable ASCII string options are shown below.
Note: Start and End strings can now accept ASCII Hex values, and the following special characters: "\r",
"\n", "\t".
DescriptionValuesOption Name
The delimiter is used to separate the
individual pieces of data being sent.
, <Comma>
: < Colon>
Delimiter
The delimiter will follow every
; <Semicolon> individual segment of data, including
start string and end string.
\r\n <CR_LF> Carriage return and
then line feed
\n\r <LF-CR> Line feed then carriage
return
\r <CR> Carriage return only
\n <LF> Line feed only
This option is a mechanism for
adding characters before a string of
data.
User-dened ASCII characters (limit
of 75 characters)
Start String
Note: ASCII Hex characters are
allowed. Special symbols such
as \r, \n, and \t will cause a
carriage return, new line, and tab
to be output repsectively.
Banner Engineering Corp.Minneapolis, MN USA248
2/2010PresencePLUS Software Tools