Scaling Range
Scaling Range allows you to set a range from a low of 0.8 to a high of 1.2. In Run mode, this will enable matches to
occur even with slight variations in shape from the reference shape.
Results
The Results eld returns the following:
Total number of shapes above the minimum acceptance level.
Position of each shape's center. The origin (0,0) is the upper-left corner of the screen.
7.3.6 Line Detect Tool
The Line Detect tool nds a single, straight-line segment. The tool works by rst nding many edge points along the
transitions between bright and dark pixels and then tting a line to some or all of those points. I can measure the length
of a straight edge, nd damage or aws along an edge or offer a way to measure between a straight line and other
points or lines in the image.
Place the Region of Interest (ROI) by clicking to one side of the line you wish to nd and then dragging the cursor
perpendicularly across that line before releasing. Adjust the width of the ROI by dragging either side.
Usage
Measure the height and width of a part
Measure the height of a needle
Measure the deection of an automotive gauge
Detect the edge of a web
Verify that a bottle cap is on completely
Find chips, spurs, or other aws along a straight edge
Measure the angle between two lines
Fields
The following are elds on the Line Detect tool Input tab:
Edges on page 157
Search For Field on page 157
Legend on page 158
Results on page 158
Supported Platforms
155Minneapolis, MN USABanner Engineering Corp.
PresencePLUS Software Tools2/2010