Engineering Light Gauging Sensors Product Brochure

More information online at bannerengineering.com
259
MEASURING
LIGHT SCREENS
TEM PER AT URE
ULTRASONIC
MEASUREMENT & INSPECTION
RADAR
LIGHT
GAUGING
L-GAGE
®
Q50 Discrete Output Specifications
Sensing Beam
Wavelength: Q50..V: 685 nm (typical) Q50..: 880 nm (typical)
Beam Size: Q50..V: 20 mm dia. (max.) Q50..: 20 mm dia. (max.)
Sensing Range
Q50AV: 50 to 150 mm Q50A: 50 to 200 mm
Q50BV: 100 to 300 mm Q50B: 100 to 400 mm
Supply Voltage and Current
12 to 30V dc (10% max. ripple); 70 mA max. (exclusive of load)
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Output Configuration
Solid-state Complementary; Choose NPN (current sinking) or PNP (current sourcing) models.
Delay at Power-up
2 seconds
Output Rating
Complementary Discrete Output 150 mA max., per output
OFF-state leakage current: Less than 10 µA
ON-state saturation voltage: Less than 1V @ 10 mA and less than 1.5V @ 100 mA
Output Protection
Protected against false pulse on power-up and continuous overload or short circuit of outputs.
Output Response Time
2-second delay on power-up:
Fast: 4 milliseconds ON/OFF Slow: 48 milliseconds ON/OFF
Output Hysteresis
See charts HC-5 and HC-6 on page 512.
Sensing Repeatability
Slow Response (Q50..): 0.5% of sensing distance
Fast Response (Q50..Y): 1.0% of sensing distance
Color Sensitivity (typical)
See charts CSC-2 and CSC-3 on page 511.
Temperature Effect
Q50B.. models: From 0° to 50° C: 0.25 mm/° C From -10° to 55° C: 0.35 mm/° C
Q50A.. models: From 0° to 50° C: 0.08 mm/° C From -10° to 55° C: 0.11 mm/° C
Remote TEACH Input
Impedance
15 kΩ
Remote TEACH Input
To TEACH: Connect gray wire to +5 to 30V dc
To Disable: Connect gray wire to 0 to +2V dc (or open connection)
Adjustments
Sensing Window Limits: TEACH-mode programming of near and far window limits may be set using
the TEACH push button or remotely using the gray TEACH wire.
Indicators
Range LED GreenTarget is within sensing range
Indicator RedTarget is outside sensing range
(Green/Red) Flashing Green — Outputs are overloaded
OFF Sensor Power OFF
Teach/Output Yellow (window limits) — Target is within taught window limits
LED Indicator Yellow (fixed field) — Target is closer than cutoff limit
(Yellow/Red) OFF Target is outside taught window limits
RedSensor is in TEACH mode
Ambient Light Immunity
< 10,000 LUX
Construction
Housing: Molded ABS/Polycarbonate Window Lens: Lens: Acrylic
Hardware: M3 hardware is included
Environmental Rating
IEC IP67; NEMA 6P
Connections
2 m or 9 m 5-conductor PVC-covered attached cable, or 5-pin Euro-style quick-disconnect.
See page 416.
Operating Conditions
Temperature: -10° to +55° C Relative humidity: 90% at +50° C (non-condensing)
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double
amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G,
11 milliseconds duration, half sine wave.
Application Notes
Allow 15-minute warm-up for maximum performance
Certifications
Hookup Diagrams
MI08 (p. 533)