Manual

L-GAGE™ Q50 Series with Analog Output
LED-Based Linear Displacement Sensor with Analog Output and TEACH-Mode
Programming
Printed in USA 03/01 P/N 64323 Rev. A
L-GAGE Q50 Analog Output Sensor Features
Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
Selectable output response speeds: 4 milliseconds or 64 milliseconds (see hookup)
•Teach a sensing window size and position, or a set-point threshold centered within
a 100 mm window
•Two sensing ranges, depending on model: 100 to 300 mm (visible red beam
models), and 100 to 400 mm (infrared beam models)
Sensor linearity is better than 3 mm
Banner’s patented scalable analog output (U.S. patent #6,122,039) automatically
distributes the output signal over the width of the programmed sensing window
Analog output slope can be either positive or negative, depending upon which
window limit is programmed first
•Two bicolor Status LEDs
Choose 2 meter or 9 meter unterminated cable, or swivel 5-pin Euro-style QD
connector
Rugged construction withstands demanding sensing environments; rated IEC IP67,
NEMA 6
Select models with either visible red or infrared beam
Select models with either a 0-10V or 4-20 mA output
L-GAGE Q50 Analog Output Sensor Models
Model
Number
Sensing
Range Cable*
Supply
Voltage Beam Output
Q50BVI
100 to 300 mm
(3.9" to 11.8")
5-wire,
2 m (6.5') cable
15 to
30V dc
Visible Red
LED
4 to 20 mA
Q50BVIQ
5-pin Euro-style QD
Q50BVU
5-wire,
2 m (6.5') cable
0 to 10V
Q50BVUQ
5-pin Euro-style QD
Q50BI
100 to 400 mm
(3.9" to 15.7")
5-wire,
2 m (6.5') cable
Infrared LED
4 to 20 mA
Q50BIQ
5-pin Euro-style QD
Q50BU
5-wire,
2 m (6.5') cable
0 to 10V
Q50BUQ
5-pin Euro-style QD
* 9 meter cables are available by adding suffix “W/30” to the model number of any cabled
sensor (e.g., Q50BRI W/30). A model with a QD connector requires a mating cable;
see page 8.
WARNING . . .
Not To Be Used for
Personnel Protection
Never use these products as
sensing devices for personnel protection.
Doing so could lead to serious injury or
death.
These sensors do NOT include the self-
checking redundant circuitry necessary to
allow their use in personnel safety
applications. A sensor failure or
malfunction can cause either an energized
or de-energized sensor output condition.
Consult your current Banner Safety
Products catalog for safety products which
meet OSHA, ANSI and IEC standards for
personnel protection.
!