User Manual
Wiring Options for Emitter/Receiver Swapability
Each EZ-SCREEN Type 2 sensor can be connected to its own power supply or, color-for-color to the other sensor’s cable. The color-for-
color hookup allows the emitter and receiver positions to be interchanged without rewiring (functionality known as sensor " swapability").
Model CSB.. splitter cordsets and DEE2R.. double-ended cables facilitate interconnection between an EZ-SCREEN Type 2 receiver and
emitter, providing a single "homerun" cable for optional swapable hookup.
Individual Cordsets Splitter Cordsets
EZ-SCREEN Type 2
Bn
Or/Bk
Or
Wh
Bk
Bu
Gn/Ye
Vi
+24V dc
C
n.c.
n.c.
OSSD2
OSSD1
0V dc
Ground
Reset/Test & EDM
A
B
D
C
A
B
Key Description
A Emitter
B Receiver
C QDE-8..D Cordsets
Key Description
A Emitter
B Receiver
C DEE2R.. Cordsets
D CSB.. Cordsets
Manual Reset/Remote Test Input and EDM
A single input provides the means to reset the system from a latch or lockout condition, to externally test the light screen and its interface,
and to monitor external devices (EDM) for proper operation. If the System is in Run condition with outputs ON, operating the switch
results in a test. If the System is Latched or Locked Out, operating the switch results in a reset.
EZ-SCREEN® Type 2 Light Screen Instruction Manual
10 www.bannerengineering.com - tel: 763-544-3164 122452 rev. B