Instruction Manual

Push Button Remote
0.04 seconds < T < 0.8 seconds
Result
Remote
Display flashes “2nd
Arrow icon turns red
SET Output
OFF Condi-
tion
Present Output OFF
condition
Five-click Static but-
ton
Present Output OFF con-
dition
Five-pulse the remote
line
T T
T
T
T
T
T
T
T
Threshold Condition Ac-
cepted
Display flashes “Sn6l,”
then "dr" twice
Sensor returns to RUN
mode with new settings
Arrow icon turns green
Threshold Condition Un-
acceptable
Display flashes “FAIL
and returns to “1St
Arrow icon remains red
After 60 seconds, sen-
sor returns to RUN
mode (Arrow icon turns
green) without chang-
ing settings
Manual Adjust
Manual Adjust is used during RUN mode and is accomplished via the push buttons only. Its behavior depends on whether a switching
threshold or a sensing window is used.
Switching Threshold:
Fine-tunes sensing sensitivity
Press “+” to increase; press “-” to decrease
Sensing Window:
Adjusts sensing window size (tolerance) for the single-point target condition
Press “+” to increase; press “-” to decrease
Push Button Remote
0.04 seconds < T < 0.8 seconds
Result
Manual Ad-
just
Click "+" to increase, or
click "-" to decrease.
or
Not available with remote
programming.
Display briefly flashes the
threshold setpoint value as
it is being changed
OR
Display flashes"inc" or
"dEc" as the window size is
adjusted
or
D10 Expert - Analog and Discrete Outputs
P/N 65448_web
rev. F
www.bannerengineering.com - tel: 763-544-3164 11