Owner's manual
Control Module Configuration
18
Banner Engineering Corp. • Minneapolis, U.S.A.
Website:http://www.baneng.com • Tel:888.373.6767
3.3.4 DeviceNet Communication Hookups
4. Control Module Configuration
TheA-GAGEMINI-ARRAYcontrolmoduleiseasilyconfiguredusingthesuppliedEDS
fileandtheuser’sDeviceNetconfigurationtool.
4.1 Communications Setup
SeeSection3.3.4,page17forinformationonconnectingtheMINI-ARRAYcontrol
moduletotheDeviceNetnetwork.
4.2 System Alignment
Theemitter/receiverpairshaveawidefieldofviewandareeasytoalign.The
recommendeddistancebetweentheemitterandreceiverrangesfrom15"to72".
(Shortersensorseparationcanbeachieved;pleaseconsultfactoryfordetails.)The
AlignmentprocessshouldbeperformedatSysteminstallationandrepeatedeverytime
oneorbothofthesensorsismoved.
AlignmentstatusiscontinuouslydisplayedbythegreenLEDindicatorsonthereceiver
andthecontroller.Whenallunblankedbeamsareclear,andexcessgainofallbeamsis
atleast3x,thegreenAlignmentindicatorswillbeON.Whentheexcessgainofoneor
morebeamsdropstobetween3xand1x,thegreenAlignLEDwillremainON,butthe
yellowLEDalsowillcomeONtoindicateawarningofmarginalalignment.Seesection
3.1formoreinformationaboutsensoralignment.
MakesurethesensorshavebeenwiredasshowninSection3.3.Applypowertothe
controlmoduleviaterminals#1and#2(16to30Vdc).
4.3 Blanking
Ifamachinefixtureorotherequipmentwillcontinuouslyblockoneormorebeams,
theaffectedbeamchannelsmaybeblanked.TheBlankingoptioncausesthecontrol
moduletoignorethestatusofblankedbeamsformeasurementmodecalculations.For
example,ifamachinefixtureblocksoneormorebeamsduringSystemoperation,the
outputdatawillbeincorrect;ifbeamsblockedbythefixtureareblanked,theoutput
datawillbecorrect.BlankingcannotbeusedwithEdgeScanmode.