3.3.1 Emitter and Receiver Hookups
Emittersandreceiversconnecttogetherinparalleltoterminals#4through#8ofthe
controlmodule(identicalforbothcontrolmodulemodels).SeeFigures3-3and
3-4forwirecolorinformation.
3.3.2 Inputs
System Power: Connectasourceof16to30Vdc,ratedat1amporgreater,tocontrol
moduleterminals#1(+)and#2(-).Connectagoodearthgroundtoterminal#3to
provideelectricalandRFnoiseimmunitytotheSystem.
NOTE:Removepowerbeforemakingotherconnectionstothecontroller.
Gate Signal: Connectaswitchedsourceof10to30Vdctoterminals#11(+)and
#12(-)toprovideagatinginput(ifrequired).Thegatingvoltagetypicallyisswitched
bytheopen-collectoroutputtransistorofadcsensingdevice.Thegatesignalcontrols
scanningwhentheGateoptionisselected(seeSection4.4).
3.3.3 Outputs
Eachcontrolmodulehastwosolid-statediscreteoutputs,labeledOutput#1and
Alarm.Bothareratedat30Vdcmax.,150mAmax.TheyareeitherbothNPNorboth
Trim braided shield flush
with cable
Trim foil shield flush
with cable
Uninsulated
drain wire
Figure 3-5. Emitter and receiver cable
preparation
NOTE:The“drainwire”istheuninsulated
strandedwirewhichrunsbetweenthe
braidedshieldandthefoilshield.Thefoil
shieldandthebraidedshieldshouldbe
removedatthepointwherethewiresexit
thecable.
Control
Module
Output #1
(Terminal #9)
Output #2 (“Alarm”)
(Terminal #15)
MACNXDN-1
Figure3-3
NPNopen-collector
30Vdcmax.
150mAmax.
NPNopen-collector
30Vdcmax.
150mAmax.
MACPXDN-1
Figure3-4
PNPopen-collector
150mAmax.
PNPopen-collector
150mAmax.
PNP,dependingonthemodel.
Terminal
Wire
Color Function
D3 – Shield
D5 Red BusPower(+V)
D1 Black BusPower(-V)
D4 White Communications+
D2 Blue Communications-
D5 D4 D3 D2 D1
DEVICENET
CONNECTIONS
V+ V-
CAN_H CAN_L
SHIELD