Owner's manual

Installation and Mechanical Alignment
16
Banner Engineering Corp. • Minneapolis, U.S.A.
Website:http://www.baneng.com • Tel:888.373.6767
3.3 Hookups
ConnectionsaremadetotheMACNXDN-1andMACPXDN-1controlmodulesvia20
wiringterminalslocatedalongthefrontsurfaceofthemodule.RefertoFigures3-3
and3-4fortheappropriatehookupinformation.
NOTE:ThecontrollermustbepoweredupbeforetheDeviceNetconnectioninevery
power-upsituation,forproperoperation.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D5 D4 D3 D2 D1
F1
V+
16 - 30V dc
1.2A MAX
EMITTER and
RECEIVER CABLES
10-30V dc
GATE
SIGNAL
OUTPUT 1
BROWN
V-
NC NC
+-
BLUE
DRAIN WIRE
BLACK
WHITE
DEVICENET
CONNECTIONS
RED
WHITE
DRAIN WIRE
BLUE
BLACK
150mA
max.
ALARM
150mA
max.
Figure 3-3. MACNXDN-1 hookup (2 NPN discrete outputs)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D5 D4 D3 D2 D1
F1
V+
16 - 30V dc
1.2A max.
EMITTER and
RECEIVER CABLES
10-30V dc
GATE
SIGNAL
OUTPUT 1
BROWN
V-
NC NC
+-
BLUE
DRAIN WIRE
BLACK
WHITE
DEVICENET
CONNECTIONS
RED
WHITE
SHIELD
BLUE
BLACK
150mA
max.
ALARM
150mA
max.
Figure 3-4. MACPXDN-1 hookup (2 PNP discrete outputs)