Control Module Configuration
Banner Engineering Corp. •Minneapolis,U.S.A.
www.bannerengineering.com•Tel:763.544.3164
To accommodate parts or components that will move through
the array,blankingmaybemanuallyadjustedforoneormore
individualbeamchannels.AfterusingtheSystemsoftwareto
specifyblanking,select‘Edit’fromtheAlignmentscreen;the
DiagnosticsIndicatorwillcontinuetoshowtheletter‘b’anda
gridwillappearonthecomputerscreen(Figure5-8).The
beamsarenumberedfromthesensors’cabledends,withthe
beamclosesttothecablebeingbeam#1.Tosettheblanking
fields,‘click’eachgridboxrepresentingabeamyouwishto
blank.
Clickingagainonablankedbeamchannelwillremovethe
blankingspecification.Rowsofchannelscanbeselectedor
clearedoftheblankingspecificationbyplacingthecursor
directlytotheleftoftherowtobeselectedandclickingthe
mouse;therowshouldbehighlighted.SelecttheBlank
Selected(toaccepttheblankingstatus)orClear Selected(to
rejecttheblankingstatus)option.ToleaveAlignmentmode,
select‘OK’.Boththecontrolmoduleandthereceiverwill
indicateaclearcondition(greenAlignindicatorON)andthe
DiagnosticsIndicatorwillshow‘A.’.WhentheSystemisready
foroperationandconfiguredforbeamstobeblanked,the
periodontheDiagnosticsIndicatorwillremainlit,showing‘—.’
(seeFigure5-4).
Figure 5-8. Edit channel blank state screen, showing beam #22 and
beams #35-42 blanked; beams #65-80 are highlighted,
ready to be selected for blanking
5.3 Programming Control Module Response
TheParameterSetupFile(PSF)Configurationroutine(seeFigure5-9)isusedto
configurethecontrolmoduleforaspecificapplication.AccessthePSFConfiguration
screen(afterperformingthePingroutinetoselectacontrolmodule,section5.1.1)by
selectingEdit PSF (F4)fromtheMINI-ARRAYmenu.TheEditPSFprocessmayalso
beperformedwithnocontrolmoduleselected,toconfigureandsaveaPSFfor
multiplecontrolmodules.Insuchacase,somefieldsonthePSFConfigurationscreen
willnotbeaccessible.
Theprocessofconfiguringthecontrolmoduleinvolvesselectingamongoptionsfor
eachoftheparameterslistedinthissection,includingserialcommunication,control
mode,scanningmethod,scananalysismode,serialtransmission,andanalog/discrete
outputs.Theresultingcombinationofoptionscausesthecontrolmoduletoreactas
requiredfortheapplication,tochangesinthelightscreen.
TheconfigurationprocessproducesaParameterSetupFile(PSF).PSFfilesmaybe
savedandretrievedascomputerfilesviatheFile Save PSFandFile Retrieve PSF
commands(seesection5.4.5).Onceconfigured,aPSFmaybesenttothecontrol
moduleviatheSend PSFcommand.Likewise,thePSFcurrentlyloadedintothe
controlmodulemaybedisplayedbyusingtheUpload PSFcommand.