5.5.1 Factory Default Settings
Table 7: General Tab Default Settings
Setting Factory Default
Response Speed Medium
Signal Strength Threshold 1.0
Target Mode Nearest Target
Measurement Hold Disabled
Discrete Output & Remote Input PNP
Remote Input Wire Disabled
Push Buttons Enabled
Table 8: Analog Tab Default Settings
Setting Factory Default
1515 Models 4545 Models 1515-C Models
Range 4 mA to 20 mA (0 V to 10 V) 4 mA to 20 mA (0 V to 10 V) 4 mA to 20 mA (0 V to 10 V)
4mA/0V Point 0.3 m (1 ft) 0.3 m (1 ft) 0.1 m (.33 ft)
20mA/10V Point 15.0 m (49.2 ft) 10 m (32.8 ft) 6 m (19.7 ft)
Loss of Signal 3.5 mA (0 V) 3.5 mA (0 V) 3.5 mA (0 V)
Averaging 1× (no averaging) 1× (no averaging) 1× (no averaging)
Table 9: Discrete 1 Tab Default Settings
Setting Factory Default
1515 Models 4545 Models 1515-C Models
Output Mode Switch Point Switch Point Switch Point
Setpoint 1 15.0 m (49.2 ft) 10 m (32.8 ft) 6 m (19.7 ft)
Hysteresis 0.05 m (2 in) 0.05 m (2 in) 0.05 m (2 in)
NO/NC Normally Open Normally Open Normally Open
On Delay 0 ms 0 ms 0 ms
Off Delay 500 ms 500 ms 500 ms
Table 10: Discrete 2 Tab Default Settings
Setting Factory Default
1515 Models 4545 Models 1515-C Models
Output Mode Switch Point Switch Point Switch Point
Setpoint 1 15.0 m (49.2 ft) 10 m (32.8 ft) 6 m (19.7 ft)
Hysteresis 0.05 m (2 in) 0.05 m (2 in) 0.05 m (2 in)
NO/NC Normally Open Normally Open Normally Open
On Delay 0 ms 0 ms 0 ms
Off Delay 500 ms 500 ms 500 ms