Figure 9. Analog Teach
Analog
SCENARIO
Teach analog
window using
taught distances
Teach 2 separate points
Teach “same” point twice
Tch1
Tch1
Tch2
Tch2
4 mA 20 mA
4 mA 20 mA
Teach analog
window from min.
settable value to
taught distance
Figure 10. Discrete Teach
SCENARIO
* Teach 2 separate points
Teach “same” point twice
Background Teach
Teach discrete
window using
taught distances
Teach switch
point in front of
taught distance
Discrete
Tch1 Tch2
SPt1 SPt2
SPt
Tch1
Tch2
Teach “same” point twice
Object Teach
Teach switch
point behind
taught distance
SPt
Tch1
Tch2
* Teach “same” point twice
* Default setting for the discrete teach
Window
Teach window
centered around
taught point
SPt1 SPt2
Tch1
Tch2
Note: Teach modes must be set with the remote input wire.
To cancel a configuration while in process, press and hold the button for the output being taught for longer than 2 seconds.
1. To enter TEACH mode, press and hold the button for the desired output.
The buttons are
Analog and Discrete (analog models) and Discrete 1 and Discrete 2 (discrete models).
The green Power LED turns OFF, the yellow LED of the output being taught turns ON, and the yellow LED of the
output not being taught turns OFF.
2. Position the target.
3. Press the button for the desired output one time to configure the first point.
The yellow LED of the output being taught flashes.
4. Position the target.
5. Press the button for the desired output one time to configure the second point.
The green Power LED turns on.
5.5 Reset the Sensor to Factory Defaults
Reset the sensor to factory default settings using one of two methods.
Note: If a factory reset is performed through the Banner Radar Configuration Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.
Reset Using the Banner Radar
Configuration Software
Go to Sensor > Factory Reset. The sensor indicators flash once, the sensor is reset back to the factory default settings, and
a confirmation message displays.
Reset Using the Remote Input
Eight-pulse the remote input to apply the factory defaults.