Cut Sheet

Specicaons
Supply Voltage and Current
Emiers: 12 to 240V ac (50/60 Hz) or 10-30V dc at 20 mA, 10% maximum
ripple
DC Receivers: 10 to 30V dc at 10 mA maximum (exclusive of load); 10%
maximum ripple
AC Receivers: 24 to 240V ac (50/60 Hz)
Supply Protecon Circuitry
Protected against reverse polarity and transient voltages
Output Conguraon
DC Receivers: Bi-Modal
output (PNP sourcing or NPN sinking). Selecon of
light/dark operate and sourcing or sinking conguraon dependent on hookup.
AC Receivers: SPST solid-state switch; light operate (LO) or dark operate (DO)
dependent on model.
Output
Rang
DC Receivers: 250 mA connuous
Output saturaon voltage (PNP & NPN conguraon) < 1 volt at 10 mA and < 2
volts at 250 mA
O-state leakage current < 10 microamps
AC Receivers: Maximum steady-state load capability is 500 mA
Inrush capability: 10 amps for 1 second (non-repeang)
O-state
leakage: current < 1.7 mA rms
On-state voltage drop: < 3.5 volts rms across a 500 mA load; < 5 volts rms
across a 15 mA load
Output Protecon Circuitry
Outputs of dc receivers are short circuit protected
Output Response Time
10 milliseconds on/o
Repeatability
“A” frequency models: 1 ms
“B” frequency models: 1.5 ms
“C” frequency models: 2.3 ms
Indicators
Internal red LED, visible through the lens or from side of the sensor.
Emiers: Red “Power ON” indicator LED
DC Receivers: Lights whenever receiver sees its modulated light source
AC Receivers: Lights whenever receiver’s output is
conducng
Construcon
Fully epoxy-encapsulated tubular threaded housing, posive sealed at both
ends, quad-ring sealed acrylic lens.
Plasc models: 30 mm diameter thermoplasc polyester housing and jam nuts.
Stainless Steel models: 30 mm diameter 303 stainless steel housing and jam
nuts.
Environmental
Rang
Exceeds NEMA 6P and IEC IP67
Connecons
PVC-jacketed 2 m or 9 m cables or Mini-style quick-disconnect (QD) ng are
available. QD cables are ordered separately.
Operang Condions
Temperature: 40 °C to +70 °C (40 °F to +158 °F)
90% at +50 °C maximum
relave humidity (non-condensing)
Required Overcurrent Protecon
WARNING: Electrical
connecons must be made
by qualied personnel in accordance with local
and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon
per the supplied table.
Overcurrent protecon may be provided with external fusing or via Current
Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For
addional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Cercaons
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Cabled Models
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
102 mm
(4.0")
QD Models
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
114 mm
(4.5")
SM30 Series 30 mm Barrel Sensors
P/N 03541 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 3