Cut Sheet
Table Of Contents
Specicaons
Supply Voltage and Current
Emiers: 12 to 240V ac (50/60 Hz) or 10-30V dc at 20 mA, 10% maximum
ripple
DC Receivers: 10 to 30V dc at 10 mA maximum (exclusive of load); 10%
maximum ripple
AC Receivers: 24 to 240V ac (50/60 Hz)
Supply Protecon Circuitry
Protected against reverse polarity and transient voltages
Output Conguraon
DC Receivers: Bi-Modal
™
output (PNP sourcing or NPN sinking). Selecon of
light/dark operate and sourcing or sinking conguraon dependent on hookup.
AC Receivers: SPST solid-state switch; light operate (LO) or dark operate (DO)
dependent on model.
Output
Rang
DC Receivers: 250 mA connuous
Output saturaon voltage (PNP & NPN conguraon) < 1 volt at 10 mA and < 2
volts at 250 mA
O-state leakage current < 10 microamps
AC Receivers: Maximum steady-state load capability is 500 mA
Inrush capability: 10 amps for 1 second (non-repeang)
O-state
leakage: current < 1.7 mA rms
On-state voltage drop: < 3.5 volts rms across a 500 mA load; < 5 volts rms
across a 15 mA load
Output Protecon Circuitry
Outputs of dc receivers are short circuit protected
Output Response Time
10 milliseconds on/o
Repeatability
“A” frequency models: 1 ms
“B” frequency models: 1.5 ms
“C” frequency models: 2.3 ms
Indicators
Internal red LED, visible through the lens or from side of the sensor.
Emiers: Red “Power ON” indicator LED
DC Receivers: Lights whenever receiver sees its modulated light source
AC Receivers: Lights whenever receiver’s output is
conducng
Construcon
Fully epoxy-encapsulated tubular threaded housing, posive sealed at both
ends, quad-ring sealed acrylic lens.
Plasc models: 30 mm diameter thermoplasc polyester housing and jam nuts.
Stainless Steel models: 30 mm diameter 303 stainless steel housing and jam
nuts.
Environmental
Rang
Exceeds NEMA 6P and IEC IP67
Connecons
PVC-jacketed 2 m or 9 m cables or Mini-style quick-disconnect (QD) ng are
available. QD cables are ordered separately.
Operang Condions
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
90% at +50 °C maximum
relave humidity (non-condensing)
Required Overcurrent Protecon
WARNING: Electrical
connecons must be made
by qualied personnel in accordance with local
and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon
per the supplied table.
Overcurrent protecon may be provided with external fusing or via Current
Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For
addional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Cercaons
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Cabled Models
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
102 mm
(4.0")
QD Models
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
114 mm
(4.5")
SM30 Series 30 mm Barrel Sensors
P/N 03541 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 3