Cut Sheet

Wiring Terminal Block
Terminal Block Key
0 = dc common
1 = Module 1
2 = Module 2
3 = Module 3
4 = Module 4
5 = Module 5
6 = Module 6
Specicaons
Supply Voltage and Current
12 V dc to 30 V dc
Indicator Color or Audible Model
Maximum Current (mA)
at 12 V dc at 30 V dc
Blue, Green, White 420 150
Red, Yellow, Orange 285 120
Standard Audible 30 30
Loud Audible (Intensity 1) 30 25
Loud Audible (Intensity 2) 50 40
Loud Audible (Intensity 3) 165 75
Loud Audible (Intensity 4) 350 120
Supply Protecon Circuitry
Protected against transient voltages
Indicators
1 to 6 colors depending on model (Green, Red, Yellow, Blue, White, and Orange)
LEDs are independently selected
Flash Rates: 1.5 Hz ±10% and 3 Hz ±10%
Indicator Response Time
O Response: 150 µs (maximum) at 12 to 30 V dc
On Response: 180 ms (maximum) at 12 V dc; 50 ms (maximum) at 30 V dc
Audible Alarm
Standard Audible: 2.6 kHz ± 250 Hz oscillaon frequency; maximum intensity (typical) 92
dB at 1 m (3.3 )
Loud Audible: 2.6 kHz ± 250 Hz oscillaon frequency; maximum intensity (typical) at 1 m
(3.3 ) (see table)
DIP Switches Max Intensity (Loud Audible)
9 10
ON ON Intensity 4: 101 dB
OFF ON Intensity 3: 99 dB
ON OFF Intensity 2: 92 dB
OFF OFF Intensity 1: 85 dB
Audible Adjustment
Standard Audible: Rotate the cover
unl the desired volume is reached
Loud Audible Alarm: Select the desired volume using DIP switches 9 and 10
Typical Reducon in Sound Intensity with Audible Adjustment (maximum to
minimum):
Standard Audible: 8 dB
Loud Audible: 16 dB
Construcon
Bases, Segments, Covers: polycarbonate
TL70 Modular Tower Light
P/N 182215 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 3