Cut Sheet

Specicaons
Supply Voltage and Current
10 to 30 V dc (10% maximum ripple)
Supply current (exclusive of load current):
Emiers, non-polarized retroreecve, retroreecve, diuse models: 25
mA
Receivers: 20 mA
Polarized
retroreecve models: 30 mA
Fixed-eld models: 35 mA
Supply
Protecon Circuitry
Protected against reverse polarity and transient voltages
Indicators
Two LEDs (green and amber):
Green on: power to sensor is on
Green ashing: output is overloaded
Amber on: N.O. output is conducng
Amber ashing: excess gain marginal (1 to 1.5×) in light condion
Construcon
Housing: PBT polyester housing
Lens: polycarbonate (opposed-mode) or acrylic (other models)
Connecons
2 m (6.5 ) integral cable; 9 m (30 ) integral cable; or 4-pin M12/Euro-style
quick-disconnect ng
Output
Conguraon
SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current
sourcing) models
Light Operate: N.O. output conducts when sensor sees its own (or the
emier’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.
(normally closed) output may be wired as a normally open marginal signal
alarm output, depending upon wiring to power supply (U.S. patent 5087838)
Output
Rang
150 mA maximum (each) in standard wiring. When wired for alarm output, the
total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp at 30 V dc
ON-state saturaon voltage: < 1 V at 10 mA dc; < 1.5 V at 150 mA dc
Output Protecon Circuitry
Protected against false pulse on power-up and
connuous overload or short
circuit of outputs
Output Response Time
Opposed mode models: 3 ms ON, 1.5 ms OFF
Retroreecve, xed-eld, and diuse mode models: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this me.
Repeatability
Opposed mode models: 375 μs
Retroreecve, xed-eld, and diuse mode models: 750 μs
Repeatability and response are independent of signal strength.
Operang
Condions
40 °C to +70 °C (40 °F to +158 °F)
90% at +50 °C maximum relave humidity (non-condensing)
Environmental Rang
Leakproof design rated NEMA 6P and IEC IP67 per IEC 60529
IP69K per DIN40050 for quick disconnect and cable models when the cables
are protected from direct spray
Vibraon and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibraon;
frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch acceleraon 10G).
Method 213B condions H&I.
Shock: 75G with unit
operang; 100G for non-operaon
Cercaons
Required Overcurrent Protecon
WARNING: Electrical connecons must be made
by qualied personnel in accordance with local
and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon
per the supplied table.
Overcurrent
protecon may be provided with external fusing or via Current
Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For addional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Accessories
4-Pin Threaded M12/Euro-Style Cordsets
Model Length Style Dimensions Pinout (Female)
MQDC-406 1.83 m (6 )
Straight
44 Typ.
ø 14.5
M12 x 1
2
3
4
1
1 = Brown
2 = White
3 = Blue
4 = Black
MQDC-415 4.57 m (15 )
MQDC-430 9.14 m (30 )
MQDC-450 15.2 m (50 )
S18 Series Sensors (DC Voltage)