Cut Sheet
Table Of Contents
Specicaons
Supply Voltage and Current
10 to 30 V dc (10% maximum ripple)
Supply current (exclusive of load current):
Emiers, non-polarized retroreecve, retroreecve, diuse models: 25
mA
Receivers: 20 mA
Polarized
retroreecve models: 30 mA
Fixed-eld models: 35 mA
Supply
Protecon Circuitry
Protected against reverse polarity and transient voltages
Indicators
Two LEDs (green and amber):
Green on: power to sensor is on
Green ashing: output is overloaded
Amber on: N.O. output is conducng
Amber ashing: excess gain marginal (1 to 1.5×) in light condion
Construcon
Housing: PBT polyester housing
Lens: polycarbonate (opposed-mode) or acrylic (other models)
Connecons
2 m (6.5 ) integral cable; 9 m (30 ) integral cable; or 4-pin M12/Euro-style
quick-disconnect ng
Output
Conguraon
SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current
sourcing) models
Light Operate: N.O. output conducts when sensor sees its own (or the
emier’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.
(normally closed) output may be wired as a normally open marginal signal
alarm output, depending upon wiring to power supply (U.S. patent 5087838)
Output
Rang
150 mA maximum (each) in standard wiring. When wired for alarm output, the
total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp at 30 V dc
ON-state saturaon voltage: < 1 V at 10 mA dc; < 1.5 V at 150 mA dc
Output Protecon Circuitry
Protected against false pulse on power-up and
connuous overload or short
circuit of outputs
Output Response Time
Opposed mode models: 3 ms ON, 1.5 ms OFF
Retroreecve, xed-eld, and diuse mode models: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this me.
Repeatability
Opposed mode models: 375 μs
Retroreecve, xed-eld, and diuse mode models: 750 μs
Repeatability and response are independent of signal strength.
Operang
Condions
−40 °C to +70 °C (−40 °F to +158 °F)
90% at +50 °C maximum relave humidity (non-condensing)
Environmental Rang
Leakproof design rated NEMA 6P and IEC IP67 per IEC 60529
IP69K per DIN40050 for quick disconnect and cable models when the cables
are protected from direct spray
Vibraon and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibraon;
frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch acceleraon 10G).
Method 213B condions H&I.
Shock: 75G with unit
operang; 100G for non-operaon
Cercaons
Required Overcurrent Protecon
WARNING: Electrical connecons must be made
by qualied personnel in accordance with local
and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon
per the supplied table.
Overcurrent
protecon may be provided with external fusing or via Current
Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For addional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Accessories
4-Pin Threaded M12/Euro-Style Cordsets
Model Length Style Dimensions Pinout (Female)
MQDC-406 1.83 m (6 )
Straight
44 Typ.
ø 14.5
M12 x 1
2
3
4
1
1 = Brown
2 = White
3 = Blue
4 = Black
MQDC-415 4.57 m (15 )
MQDC-430 9.14 m (30 )
MQDC-450 15.2 m (50 )
S18 Series Sensors (DC Voltage)