Cut Sheet

Action Result
Push and hold the Speed push button for 10 seconds to enter
programming mode.
Response LED flashes:
Flashing Amber — Temperature Compensation is
enabled (default).
Flashing Red — Temperature Compensation is disabled.
Click the Speed button to toggle between enable and disable. Response LED flashes:
Flashing Amber — Temperature Compensation is
enabled (default).
Flashing Red — Temperature Compensation is disabled.
Push and hold the Speed button for 10 seconds to return to Run
mode.
Sensor stores selection.
Sensor returns to Run mode.
Response LED returns to a solid color or OFF to indicate
current Output Response Time setting.
Wiring
Cabled Models
QD Models
Normally Open/Pump-In Normally Open/Pump-In Key
Load
4
5
1
3
2
85-264 V ac, 50/60 Hz
48-250 V dc**
shield*
Output Current
8 A Max.
4
5
1
3
2
shield*
Output Current
(4 A or 8 A Max.)***
Load
85-264 V ac, 50/60 Hz
48-250 V dc**
1 - brown
2 - white
3 - blue
4 - black
5 - yellow
Normally Closed/Pump-Out Normally Closed/Pump-Out Key
4
5
1
3
2
shield*
Output Current
8 A Max.
Load
85-264 V ac, 50/60 Hz
48-250 V dc**
4
5
1
3
2
shield*
Load
Output Current
(4 A or 8 A Max.)***
85-264 V ac, 50/60 Hz
48-250 V dc**
1 - brown
2 - white
3 - blue
4 - black
5 - yellow
* Banner recommends that the shield wire be connected to earth ground.
** DC wiring is without regard to polarity
*** 4 A maximum for sensors with Micro-style quick disconnects; 8 A maximum for sensors with Mini-style quick
disconnects.
Status Indicators
Power ON/OFF LED (Green) — ON when sensor power is ON.
Signal LED (Red) — indicates incoming signal strength and condition.
Signal LED Status
Indicates
ON Bright Good signal
ON Dim Marginal signal strength
OFF No signal is received
2
or target is beyond the sensor's range limitations
Output LED (Amber or Red) — indicates the target position relative to the window limits, or TEACH mode status.
U-GAGE
®
QT50UVR Series Sensors