Cut Sheet
Table Of Contents
The percentage of
deviaon indicates a change in the cuto point for either 18% gray or 6% black targets, relave to the cuto point set
for a 90% reecve white test card.
For example, the cuto point decreases 4% for a 6% reectance black target when the cuto point is adjusted for 1000 mm (40 in) using
a 90% reectance white test card. In other words, the cuto point for the black target is 960 mm (38 in) for this seng.
0
-1
-2
-3
-4
-5
200 300 400 500 600 700 800 900 1000
Cutoff Setting (90% White Card)
Percent Deviation
18% Gray Card
6% Black Card
Figure 9. Cuto Point Deviaon
150
140
130
120
110
100
90
80
70
60
50
200 400 600 800 1000
Cutoff Distance (mm) with 90% White Card
Minimum Range with a 6% Black Card (mm)
Figure 10. Q60 Minium Range Versus Cuto Seng
2.0
1.5
1.0
0.5
0
200 400 600 800 1000
Cutoff Setting (mm) with 90% White Card
Hysteresis (% of Cutoff) with 6% Black Card
Figure 11. Hysteresis
Conguring a Sensor
Set the Output Delay
The output of the A60AFV sensor may be delayed between 0.008 and
16 seconds, in any of 72 increments. Delay is indicated on the 5-
segment light bar using single LED segments or combinaons of them,
in varying stages of intensity.
To set a delay, single-click the appropriate buon or pulse the remote
wire to enable the process (as described in the following procedures).
Then use the + or – buon or the appropriate remote wire pulse
procedure to increase or decrease the delay (single-click adjusts the
delay by one step at a me, and holding the buon in provides a rapid
increase/decrease).
Note: Remote wire available on models
Q60BB6AFV(Q1) only.
Major increments, displayed by a single full-intensity LED, are
shown:
Step # Delay Time LED Status
0 No Delay
DO
SIG
LO
8 0.062 second
DO
SIG
LO
24 0.250 second
DO
SIG
LO
40 1.00 second
DO
SIG
LO
56 4.0 seconds
DO
SIG
LO
72 16 seconds
DO
SIG
LO
Q60AFV Series Sensors with Visible Red Emier
P/N 69622 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 5