Cut Sheet
Table Of Contents
Installaon
Wiring Diagrams
Q60BB6xx(Q)
Cabled and QD Models, 10 to 30 V dc
3
1
2
4
5
10-30V dc
Remote
Program
Load
Load
+
–
Q60VR3xx
Cabled Model, 24 to 250 V ac (50/60Hz) or 12 to 250 V
dc
3
5
2
N.C.
C
N.O.
1
4
24 - 250V ac or 12 - 250V dc
Key
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
Q60VR3xxQ1
QD Model, 24 to 250 V ac (50/60Hz) or 12 to 250 V dc
24-250V ac
or 12-250V dc*
*NOTE: Connection of dc power is without regard to polarity.
1
N.O.
C 3 A max. load
2
3
4
Key
1 = Red/Black
2 = Red/White
3 = Red
4 = Green
Set the Cuto Distance
The cuto distance for A60AFV sensors can be adjusted between 200 mm to 1000 millimeters (8 in to 40 in).
To maximize contrast, posion the lightest possible background to be used, at the closest posion it will come to the sensor during use.
Using a small screwdriver in the adjustment screw, adjust the cuto distance unl the threshold is reached and the green Light Sensed
indicator changes state. If the indicator never turns ON, the background is beyond the maximum sensing cuto and will be ignored.
Note the posion of the rotang
cuto posion indicator at this posion. Then repeat the procedure, using the darkest target, placed in
its most distant posion for sensing. Adjust the cuto so that the indicator is midway between the two posions.
Target Background
Cutoff
Distance
E
R2
R1
Figure 3. Set the cuto distance approximately midway between the
farthest target and the closest background
ON
OFF
DELAY
DELAY
DO
SIG
LO
RANGE
I
n
c
r
e
a
s
i
n
g
D
i
s
t
a
n
c
e
Set Cutoff Midway
Between
Farthest Target Object
Closest Background
Figure 4. Seng the cuto distance
Note: Seng the cuto distance adjustment screw to its maximum clockwise posion places the receiver lens
directly in front of the receiver elements and results in the Q60 performing as a long-range diuse sensor.
Q60AFV Series Sensors with Visible Red Emier
P/N 69622 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 3