Cut Sheet

Conguring a Sensor
Set the Output Delay
The output of the Q60LAF sensor may be delayed between 0.008 and
16 seconds, in any of 72 increments. Delay is indicated on the 5-
segment light bar using single LED segments or combinaons of them,
in varying stages of intensity.
To set a delay, single-click the appropriate buon or pulse the remote
wire to enable the process (as described in the following procedures).
Then use the + or – buon or the appropriate remote wire pulse
procedure to increase or decrease the delay (single-click adjusts the
delay by one step at a me, and holding the buon in provides a rapid
increase/decrease).
Major increments, displayed by a single full-intensity LED, are
shown:
Step # Delay Time LED Status
0 No Delay
DO
SIG
LO
8 0.062 second
DO
SIG
LO
24 0.250 second
DO
SIG
LO
40 1.00 second
DO
SIG
LO
56 4.0 seconds
DO
SIG
LO
72 16 seconds
DO
SIG
LO
Increase or Decrease the ON Delay
T = 40 – 800 ms
Press and Hold > 800 ms unless otherwise noted
Increase the ON Delay—4-second me-out
Enter ON Delay Setup Enable Delay Increment Step Increment Rapid Increment
Push Buon
ON
OFF
DELAY
DELAY
+
Single-Click
N/A
ON
OFF
DELAY
DELAY
+
Single-Click
ON
OFF
DELAY
DELAY
+
Press and Hold
Remote Input
T >800 ms
T >800 ms
T >800 ms
>800 ms
Decrease the ON Delay—4-second me-out
Enter ON Delay Setup Enable Delay Decrement Step Decrement Rapid Decrement
Push Buon
ON
OFF
DELAY
DELAY
+
Single-Click
N/A
ON
OFF
DELAY
DELAY
+
Single-Click
ON
OFF
DELAY
DELAY
+
Press and Hold
Remote Input
T >800 ms
T T >800 msT
T >800 ms
>800 ms
Increase or Decrease the OFF Delay
T = 40 – 800 ms
Press and Hold > 800 ms unless otherwise noted
Q60LAF Series Laser Adjustable-Field Sensors
6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 114348 Rev. A