Cut Sheet
Table Of Contents
Specifications
Supply Voltage and Current
10 V dc to 30V dc (10% maximum ripple), at less than 50 mA
(exclusive of load)
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Bipolar: one current sourcing (PNP) and one current sinking (NPN)
open-collector transistor
Output Rating
250 mA maximum each output up to 50 °C, derated to 150 mA at
70 °C (derates 5 mA/°C)
Off-state leakage current less than 1 µA
Output saturation voltage (both outputs) less than 1 V at 10 mA and
less than 2 V at 250 mA
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or
short circuit of outputs
Output Response Time
Opposed mode: 2 milliseconds ON, 1 millisecond OFF
All other sensing modes: 2 milliseconds ON/OFF
NOTE: 100 millisecond delay on power-up.
Output is non-conducting during this time.
Repeatability
Opposed mode: 0.25 milliseconds
All other sensing modes: 0.5 milliseconds
Response time and repeatability specifications are independent of
signal strength.
Adjustments
Beneath sensor’s transparent cover: Light/Dark Operate select switch
and multi-turn Sensitivity control (allows precise sensitivity setting –
turn clockwise to increase gain). Optional logic and logic/display
modules have adjustable timing functions (see Output Timing Logic and
Signal Strength Display Modules on page 9)
Indicators
Indicator LEDs are clearly visible beneath a raised transparent Lexan
®
dome on top of the sensor.
Power (green) LED lights whenever 10 V dc to 30V dc power is applied,
and flashes to indicate output overload or output short circuit
Signal (red) AID
™
System LED lights whenever the sensor sees its
modulated light source, and pulses at a rate proportional to the
strength of the received light signal
Load (amber) LED lights whenever the output is energized
Optional 7-element LED signal strength display modules
Construction
Molded reinforced thermoplastic polyester housing, o-ring-sealed
transparent Lexan
®
3
cover, molded acrylic lenses, and stainless steel
hardware. Designed to withstand 1200 psi washdown. The base of the
cabled models has a ½-inch NPS integral internal conduit thread.
Environmental Rating
NEMA 6, IEC IP67
Connections
PVC-jacketed 2 m (6.5 ft) or 9 m (30 ft) cables; or 4-pin Mini-style
(“Q” suffix models) or 4-pin Euro-style (“Q5” suffix models) quick-
disconnect (QD) fittings are available. QD cables are ordered
separately.
Operating Conditions
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
90% at +50 °C maximum relative humidity (non-condensing)
Application Notes
Optional output timing modules are available. See Output Timing Logic
and Signal Strength Display Modules on page 9.
Certifications
Dimensions
Opposed, Retro, and Diffuse Sensing Modes (Model Suffix E, R, D, DL, DX, LP, and LV)
Cabled Models Mini-Style Quick-Disconnect
Models
Euro-Style Quick Disconnect
Models
54.1 mm
(2.13")
44.5 mm
(1.75")
69.0 mm
(2.72")
87.6 mm
(3.45")
Internal Thread
(1/2–14NPSM)
30.0 mm
(1.18")
ø 6.1 (0.24")
2m (6.5') Cable
7.1 mm
(0.28")
4.5 mm (#10) Screw
Clearance (2)
50.8 mm
(2.00")
6.4 mm (0.25")
Lens Centerline
External thread (M30 x 1.5)
hex nut supplied
External Thread
M30 X 1.5
Mini-style QD Connector
14 mm (0.6")
15 mm (0.6")
Euro-style
QD Connector
3
Lexan
®
is a registered trademark of General Electric Co.
Q45BB6 Series Sensors