User's Manual

Wiring
shield (QD cordset)
3
1
2
4
5
12-30V dc
Load 1
Load 2
+
Wiring Key:
1. Brown
2. White
3. Blue
4. Black
5. Gray (Do not connect)
NOTE: Banner recommends that the shield wire
(QD cordsets only) be connected to earth ground
or dc common. Shielded cordsets are
recommended for all QD models.
Accessories
Quick Disconnect (QD) Cordsets
5-Pin Threaded M12/Euro-Style Cordsets—with Shield
Model Length Style Dimensions Pinout (Female)
MQDEC2-506 1.83 m (6 ft)
Straight
44 Typ.
ø 14.5
M12 x 1
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
MQDEC2-515 4.57 m (15 ft)
MQDEC2-530 9.14 m (30 ft)
MQDEC2-550 15.2 m (50 ft)
MQDEC2-506RA 1.83 m (6 ft)
Right-Angle
32 Typ.
[1.26"]
30 Typ.
[1.18"]
ø 14.5 [0.57"]
M12 x 1
MQDEC2-515RA 4.57 m (15 ft)
MQDEC2-530RA 9.14 m (30 ft)
MQDEC2-550RA 15.2 m (50 ft)
NOTE: Pin 5 is not used.
Brackets and Other Accessories
SMBQ240SS2
Add-on accessory to be
used in conjunction with
SMBQ240SS1
Provides ± 20° of tilt in
second axis for maximum
control of sensor alignment
12 gauge stainless steel
Q240WS
Coated to help repel water
and maximize signal
strength
Snap-on cover for easy
application and replacement
R-GAGE
Q240RA-AF2 Sensor
8 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 184564 Rev. A