User's Manual

Zone 2 Distance Offset from Zone 1
A5 A6 A7 Offset
0 0 0 2 m (6.6 ft)
0 0 1 4 m (13.1 ft)
0 1 0 6 m (19.7 ft)
0* 1* 1* 8 m (26.2 ft)
1 0 0 10 m (32.8 ft)
1 0 1 15 m (49.2 ft)
1 1 0 20 m (65.6 ft)
1 1 1 25 m (82.0 ft)
NOTE: Highest sensitivity is achieved only if the sensing distance is 36 m (118.1 ft) or less.
Sensitivity Selection
B1 B2 B3 Sensitivity
0 0 0 8 (Highest)
0 0 1 7...
0 1 0 6 (High)
0 1 1 5...
1 * 0 * 0 * 4 (Medium)
1 0 1 3...
1 1 0 2 (Low)
1 1 1 1 (Lowest)
* Default settings
NOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft)
Output Configuration
A8
NPN / PNP
0* NPN
1 PNP
* Default settings
B7 Normally Open / Closed
0* NO
1 NC
Response Speed
B4
B5 B6 ON Total (ms) OFF Total (ms) Total (ms)
0 0 0 15 15 30
0 0 1 30 70 100
0 1 0 30 120 150
0* 1* 1* 50 300 350
R-GAGE
Q240RA-AF2 Sensor