DIP Switch Functions
Switches Function
A1, A2, A3, A4 Zone 1 Distance (detects objects from sensor face to this point)
A5, A6, A7 Zone 2 Distance, Offset from Zone 1
A8 Polarity
B1, B2, B3 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)
B4, B5, B6 Response Speed
B7 Normally Open/Normally Closed output functionality
B8 Not Used
DIP switch 1 is on the left and DIP switch 8 is on the right.
Distance Settings
Zone 1 Distance
A1 A2 A3 A4
Distance
CN US
0 0 0 0 2 m (6.6 ft) 3.5 m (11.5 ft)
0 0 0 1 2.5 m (8.2 ft) 4 m (13.1 ft)
0 0 1 0 3 m (9.8 ft) 4.5 m (14.8 ft)
0 0 1 1 3.5 m (11.5 ft) 5 m (16.4 ft)
0 1 0 0 4 m (13.1 ft) 5.5 m (18.0 ft)
0 1 0 1 5 m (16.4 ft) 6 m (19.7 ft)
0 1 1 0 6 m (19.7 ft) 6.5 m (21.3 ft)
0 1 1 1 7 m (23.0 ft) 7 m (23.0 ft)
1* 0* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft)
1 0 0 1 10 m (32.8 ft) 10 m (32.8 ft)
1 0 1 0 12 m (39.4 ft) 12 m (39.4 ft)
1 0 1 1 14 m (45.9 ft) 14 m (45.9 ft)
1 1 0 0 16 m (52.5 ft) 16 m (52.5 ft)
1 1 0 1 20 m (65.6 ft) 20 m (65.6 ft)
1 1 1 0 25 m (82.0 ft) 25 m (82.0 ft)
1 1 1 1 30 m (98.4 ft) 30 m (98.4 ft)
* Default settings
R-GAGE
™
Q240RA-AF2 Sensor
P/N 184564 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 3