Installation guide

Technical specications 56
Technical specications Master Link Gateway
Type survey
Power supply 100 ~ 230 V AC, 50/60 Hz
Power consumption Typical 2.5 Watts, standby not possible
Operating conditions -10 to +50 degrees celcius
Dimensions 35.5 x 4.5 x 15 cm (W x H x D)
48.3 x 4.5 x 15 cm (W x H x D - including bracket for rack-mount)
Weight 1.63 kg
Connections
Mains inlet
Too see the different types of mains leads see exploded view in the
Retail Ordering System
MASTER LINK Pin 1 Data- -0.4V ±0.1V
Pin 2 Data+ +0.4V ±0.1V
Pin 3 ML sense
Pin 4-8 N.C.
Pin 9 ATI transmit (N.C.)
Pin 10 ATI receive (N.C.)
Pin 11 N.C.
Pin 12 +supply voltage +7V to +15V (in St By +3V to +15V)
Pin 13 N.C.
Pin 14 N.C.
Pin 15 N.C.
Pin 16 N.C.
Market Variant Type number
Albania, Argentina, Australia, Austria, Azerbaijan, Bahrain, Belgium, Botswana, Brazil, Bulgaria, Caribbean Islands of the Dominican Repub., Canada, Chile, Croatia, Czech
Repub., Denmark, Dubai, Egypt, Estonia, Faroe Islands, Finland, France, Georgia, Germany, Ghana, Greece, Greenland, Holland, Hong Kong, Hungary, Iceland, India,
Indonesia, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Korea, Kuwait, Latvia, Lebanon, Liechtenstein, Lithuania, Luxembourg, Malaysia, Mexico, Morocco, New Zea-
land, Nigeria, Norway, Oman, Pakistan, Panama, Peru, Philippines, Poland, Portugal, Qatar, Romania, Russia, Saudi Arabia, Serbia, Singapore, Slovak Rep., Slovenia, South
Africa, Spain, St. Martin, Sweden, Switzerland, Taiwan, Thailand, Turkey, UK, Ukraine, Uruguay, United Arab Emirates, USA, Uzbekistan, Vietnam
All 1701, 1799
China (for information regarding RoHS directive please see next page)* CN 1702, 1798
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Live
Neutral