Installation guide
Supported devices 46
Vantage
Connection to a Vantage system
Communication with a Vantage system is done through an InFusion Dim Controller. This device has both RS232 and Ethernet interfaces.
Connection to the RS232 interface can be done directly using a fully wired RS232 cable and it is xed at no parity, 1 stop bit, 8 data bits. Make
sure to congure bit rate and ow control as needed. Connection settings for Ethernet are the IP address of the InFusion Dim Controller and its
telnet port.
Dening Vantage resources
To program the InFusion Dim Controller, the PC tool Design Center is needed. It lets you dene all components of your Vantage system, where
each one has an address called VID (Vantage Identication Number).
On MLGW you can dene as resources either a button on any control, or a task. To dene a resource, you need to know the Button or Task vid,
wich must be entered in the ID eld.
Vantage events and commands
An event corresponds to a Button press or release, or a Task activation or deactivation. Supported commands are Button press and release,
Button press, Button release and Task activation.