Installation guide

Programming 22
KNX / EIB:
The KNX controller only supports one user on the system (web interface) at a time. This means that the ML Gateway must be disconnected from
the network when web interface is accessed (e.g. when the denition le is transferred to the service PC or when programming the device).
When the denition le is exported to the service PC, reconnect the ML Gateway to the network and continue with the conguration below:
- Enter the IP address for the controller
- Enter the IP port for the controller
- Click Save settings
- Enter the Group address for the resource
- Choose the Data type (Boolean is default)
- Click Apply changes.
- Click the Browse button in the Resources section
(a pop up box for choose destination le appears).
- Choose the denition le from the project and click
Open.
- Choose replace or append according to the
situation.
- Click the Upload CSV resource le button and the
project le is loaded to the Resource section.
- Select the desired resources (with checkmarks in the boxes).
- To nish the selection click the Add selected resources button
The conguration and resource screen now appears on the screen, where the selected resources are visible.