Installation guide
Programming 21
- Refer to the System information window and conrm that the software version is
2.7.166 or higher
! If the software version is older than version 2.7.166 the IHC controller must be updated to
the newest version. Contact the home automation installer to update the IHC controller.
- Choose Access control from the LK IHC Administrator menu - Put a checkmark in the box for Open for third party products
The IHC controller is now ready to commnuicate with ML Gateway. Disconnect the USB cable from the service PC and the ML Gateway. The next
step is to load the IHC denition le to the ML Gateway.
- Reconnect the Service PC to the network and access the web-based user interface
(by typing the IP address for ML Gateway in a web browser).
- Go to Programming -> Devices -> IHC/LexControl
- Type an optional description and the IP address for the controller
- Click the Add resources... button in the Resources section.
- Click the Browse button to open the Open popup window.
- Choose the denition le from the project and click Open (contact the home automation
installer regarding how to export the denition le to the service PC).
- Click the Load button and the project le is loaded to the Resource section.