Installation guide

Programming 20
! RS232:
Only one system can be connected to the interface at a time, so when conguring ML Gateway, only one system on RS232 is allowed to be set up.
It is very important that the RS232 settings t the settings for the connected device.
If RS232 is the preferred connection type, and if the message RS232 port in use by ML Gateway Protocol appears on the screen, it is because
MLGW protocol over RS232 in enabled. For this connection type it is necessary to disable MLGW protocol over RS232, under System -> MLGW
Protocol.
- Click the Save settings button to apply the settings.
Resources - Home automation system
The purpose of resources here is to identify the conguration (components) of the home automation system. All resources tables contain an empty
last row. Use this row to dene new resources. Most drivers allow automatic detecting of resources, others must be added manually by uploading
a denition le. Some drivers supports both functions.
Auto conguration
- Click the Test button to start testing the conguration.
- Activate one or more of the resources (e.g. press a button on a keypad).
This must be done for each button to be used in the conguration.
- When all resources have been added the conguration, click the Cancel button
to stop the test function.
- Click the Show detected button that appears below the resources table (a new list will appear with the resources detected during the test).
- Select the resources to add to the resource tables and press Apply changes.
Manual conguration
Drivers that do not support the auto conguration function does not have the Show detected button (e.g. Lauritz Knudsen - IHC/Schneider,
LexControl). In this case, a denition le containing the conguration of the home automation system, must be uploaded to the ML Gateway.
IHC:
Before continuing adding resources, ensure the IHC controller has software version 2.7.166 or newer. This is necessary in order to be able to
connect and communicate with the controller. To check the software version, follow the procedure below:
- Connect the IHC controller with a USB cable to the service PC.
- Open Internet Explorer, type USB in the address bar and press enter.
(LK IHC Control interface appears)
- Choose LK IHC Administrator