Installation guide

Programming 19
Devices - Home automation system
Use the Devices tab to specify the devices connected to ML Gateway. For information regarding supported devices please refer to page 34, and
then follow the procedure below:
- Click on the tab Programming and then Devices.
- Click in the eld for Add new device. The following options are available:
- Clipsal
- Conson XP
- Custom strings (up to 4 drivers)
- Dynalite
- IP Camera
- KNX / EIB
- Lauritz Knudsen, IHC, Schneider, LexControl
- Legrand / BTicino
- Lutron Grak Eye
- Lutron Grak QS
- Lutron HomeWorks
- Lutron HomeWorks QS / Radio Ra2
- Lutron Radio RA
- Scheduler** (see link)
- SmartHouse
- Vantage
- Choose the relevant supported device and click the Add button. The
Conguration box (and Resource box) for the chosen device now appars
on the screen.
- Fill in the empty conguration elds which are necessary for ML Gateway
to communicate with the supported device. The number of options may
vary depending on the device.
! Refer to the next page regarding limitations of RS232 connection
Connection method RS232 / RS232 over ethernet / Ethernet
IP address xxx.xxx.xxx.xxx
IP Port xxxx
Login xxxx
Password xxxxxxxx
Bit rate 9600 / 19200 / 38400 / 57600 / 115200
Hardware ow control: x
Data bits 7 bits / 8 bits
Parity No parity / Odd / Even
Stop bits 1 bit / 2 bit
continues on next page...
Options
for
Ethernet
Options
for
RS232