Installation guide

Setting up ML Gateway / Programming 17
Restarting ML Gateway on factory-installed software
If a software update causes ML Gateway to fail (for example due to power failure during ash update), the unit can be restarted using the original
factory-installed software.
To do this, switch ML Gateway off, and while pressing the setup button, switch it back on. Release the setup button after 5 seconds. This will start
the system using the original factory software, but will not x nor replace the ‘broken’ software. You need to log into the system and perform a
software upgrade to x the broken software.
If you suspect that the failure is inherent to the latest software installed (and not a failure during the ash process), you can manually download an
earlier software version from BeoWise to your computer, and perform a software update from that le.
Software update complete
When it is conrmed that ML Gateway has the latest software, the next step is to dene devices and resources. Please follow the procedure on the
next page.
Programming
Additional information
The programming section provides the opportunity to dene how BeoLink products and the home automation systems interact.
The programming section in ML Gateway consists of two main elements:
- Devices (including Resources for BeoLink, Virtual buttons, Home automation system)
- Macros
Refer to the following pages for information about setting up devices and resources. Macros is not described since this is individually for each
home automation system.