User's Manual
COBALT UHF-SERIES CHAPTER 5: COMMAND PROTOCOLS
PAGE 87 OF 140
5.6 ERROR CODE TABLE
ERROR
CODE
ERROR DESCRIPTION
0x04
FILL TAG FAILED Fill Tag operation failed
0x05
READ DATA FAILED Read Data operation failed
0x06
WRITE DATA FAILED Write Data operation failed
0x07
TAG NOT FOUND, TAG SEARCH
FAILED
Read Tag ID operation failed, Tag
Search operation failed
0x21
INVALID SYNTAX Command Contained a syntax error
0x30
INTERNAL CONTROLLER
ERROR
Generic internal controller error
0x31
INVALID CONTROLLER TYPE Invalid controller type (when setting
configuration)
0x32
INVALID PROGRAMMING
ADDRESS
Invalid tag programming address
specified
0x35
INVALID RESET Invalid hardware reset
0x36
SET CONFIGURATION ERROR
Configuration not written
0x37
GET CONFIGURATION ERROR
Configuration not read
0x83
COMMAND INVALID OPCODE Invalid Command ID specified in the
command.
0x84
COMMAND INVALID
PARAMETER
A parameter specified in the command
was invalid.
0x85
COMMAND INVALID
CONTROLLER ID
An invalid Node ID was specified in the
command, or no controller was
detected/present at the specified Node.
0x86
COMMAND INACTIVE
CONTROLLER ID
The Node ID specified in the command
is currently inactive.
0x87
SUBNET DEVICE SELECT
FAILED
Internal Subnet Error – the specified
Subnet device failed.
0x88
SUBNET DEVICE FAILED TO
ACKNOWLEDGE
Internal Subnet Error - the specified
Subnet device failed to respond to the
Cobalt’s polling.