User's Manual
COBALT UHF-SERIES CHAPTER 5: COMMAND PROTOCOLS
PAGE 78 OF 140
COMMAND 0X C3 - DESCRIPTION
The Write EPC Command instructs the controller to write the EPC memory area of a
single tag UHF Class1 Gen2.
C
OMMAND 0X C3 - CBX EXAMPLE
This example instructs the controller to write the specified bytes in the EPC memory
of a tag. A Timeout Value of 2 seconds (0x07D0 = 2000 x one-millisecond
increments) is set for the completion of the command.
Command from Host
PARAMETER FIELD MSB LSB
Overall Length of Command
(in words)
0x00 0x0A
0xAA
in MSB
Command ID
in LSB (0x06)
0xAA 0xC3
0x00
in MSB
Node ID
in LSB
0x00 0x01
Timeout Value
(measured in ms)
0x07 0xD0
EPC Write Data
(bytes 1 and 2)
0x48 0x45
EPC Write Data
(bytes 3 and 4)
0x4C 0x4C
EPC Write Data
(bytes 5 and 6)
0x58 0x45
EPC Write Data
(bytes 7 and 8)
0xAB 0x6F
EPC Write Data
(bytes 9 and 10)
0x4E 0x45
EPC Write Data
(byte 11 and 12)
0x4F 0x00
CBX SINGLE-TAG RFID COMMAND 0X C3:
WRITE EPC CODE