User's Manual

COBALT UHF-SERIES CHAPTER 6: ETHERNET/IP INTERFACE
PAGE 110 OF 140
Common Services
Implementation Service
Code
Class Level Instance Level
Service Name
0x05
No Yes Reset*
0x0E
Yes Yes Get Attribute Single
0x10
No Yes Set Attribute Single
*This Service Code is used to flush all attributes to zero.
6.9.3 Application Object (0x67
10 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name / Description Data Type Default Data
Value
Access
Rule
1
Revision UINT 1 Get
Instance Attributes (Instances 1-32)
Attribute
ID
Name / Description Data Type Default Data
Value
Access
Rule
1 Instance Type (0-3):
0 - Disable
1 – ControlLogix
2 – SLC 5/05
3 – PLC5E
USINT 0 Get
2 PLC IP Address
UDINT 0 Get
3 PLC Slot Location (0-255)
USINT 0 Get
11 Max Write Size in Words:
0 – Disabled
1 – 100 Words
UINT 0 Get
12 Write Tag Name (ControlLogix
Only)
SHORT
STRING
0 Get
13 Write File Number (SLC/PLC
Only)
NX:0 - where “X” is the File
Number
UINT 7 Get
14 Write File Offset (SLC/PLC
Only)
N7:Y - where “Y” is the File
Offset
UINT 0 Get