Service manual
IMl035
4.
Low
voltage
bus
incorrect
(for
units
with
a low
voltage
supply)
AI,
A2
NOTE:
Low
voltage
supply
will
indicate
low
or
"0"
volts
if
an abnormal
load
is
evident
on
the
15
volt
line.
5.6
RASTER
SHIFTING
The
extra
cost
factory
option
of
inserting
Rl13
or
R1l5 makes
possible
a
fixed
raster
shift
either
down
or
up by
allowing
a
fixed
DC
current
to
flow
in
the
deflection
coil.
This
option
precludes
the
need
for
using
the
centering
rings
for
non-standard
centering
which would
result
in
disturbance
of
geometry and
focus.
1.
Raster
pull
down
(Refer
to
figure
5-1)
Add
Rl13 from
J102-4
to
ground
in
holes
provided.
Value
to
be
selected
for
desired
amount
of
pull
down.
2.
Raster
pull
up
(Refer
to
figure
5-1)
5-2
Replace
C106
with
a jumper
wire.
Remove
jumper
wire
from
J102-3
and
J102-1
and
replace
with
C107,
470uf,
10v,
electrolytic.
Add
Rl15 from
J102-3
to
ground
in
holes
provided.
Value
of
Rl15
to
be
selected
for
desired
amount
of
pull
up.