Service manual
IMI015
POWER
SUPPLY
Input
voltage:
Input
Power:
Output
voltage
ENVIRONMENTAL
Temperature:
Humidity:
Altitude:
100
to
240
AC,
50/60
Hz
46W
Nominal
+57
VDC
short
circuit
protected
+18
KV
nominal
Operating
range:
5
0
C
to
55
0
C
ambient
Storage
range:
-40oC
to
65
0
C
ambient
5
to
80%
(non-condensing)
Operating:
up
to
10,000
ft.
S
tor
age
:
up
to
14,
00 C
ft.
1.3
MECHANICAL
SPECIFICATION
Front
panel
controls:
Remaining
controls:
MODEL
TD23M
TD12C
TD12M
HEIGHT
18"
9-1/16"
10-5/16"
Off/On,
brightness
and
contrast
controls
Internal
DIMENSIONS
(NOMINAL)
WIDTH
23-1/16"
11-7/16"
12"
DEPTH
WEIGHT
(lbs)
18-1/2"
65
12-1/2"
15
12-13/16"
25
1.4
HUMAN
FACTORS
SPECIFICATION
1.4.1
X
Radiation
This
monitor
complies
with
the
Federal
Regulation
for
Radiation
as
required
by
the
Radiation
for
Health
and
Safety
Act
of
1968 and as implemented
by
title
21,
subchapter
J
of
The
Code
of
Federal
Regulations.
These
regulations
place
certain
requirements
on
manufacturers,
dealers,
and
distributors
of
products
which can emit X-rays under
some
conditions
of
operation
or
failure.
Critical
components (shaded
on
the
schematic) must be
replaced
with
EDD
approved components.
Title
21
of
the
code
of
Federal
Requlations,
part
1002
specifies
that
dealers
and
distributors
must keep
sales
records
for
all
electronic
products
which
are
subject
to
the
Federal
Radiation
Safety
Performance
Standards
to
permit
tracing
of
specific
television
recievers
to
;;pecific
purchasers.
(RefJ.
HEW
publication
(FDA)
78-8044,
Federal
Record Keeping Requirements).
1-2