Operating instructions
7
EUROPE:
The EE300Ex transmitter fulfils the ATEX Directives on intrinsically safe operating equipment.
Applied standards for ATEX:
• EN 1127-1:2011
• EN 60079-0:2012
• EN 60079-11:2012
The EC type approval test has been carried out by TÜV SÜD Product Service GmbH.
Certified to EC type approval test TPS 13 ATEX 38892 003 X.
Entity parameters U
i
= 28V; I
i
= 100mA; P
i
: = 700mW; C
i
= 2,2nF; L
i
≈0mH
Ex-Designation
Transmitter without display II 1 G Ex ia IIC T4 Ga / II 1 D Ex ia IIIC T80°C Da
Transmitter with display II 2 G Ex ia IIC T4 Gb / II 1 G Ex ia IIB T4 Ga
Remote sensing probe II 1 G Ex ia IIC T6-T1 Ga / II 1 D Ex ia IIIC T80°C...200°C Da
Working temperature range for the probes:
Specification of the temperature class "TKG" for use in gas area exposed to explosion hazards
and "TKD" for use in dust area exposed to explosion hazards as a function of the ambient
temperature "Tamb" for the humidity and temperature probe and the temperature probe:
INTERNATIONAL:
Applied Standard for IECEx:
• IEC 60079-0:2011
• IEC 60079-11:2011
The Certificate of Conformity has been carried out by FM Approvals.
Certificate No.: IECEx FMG 14.0017 X
Entityparameters: 6.4Vdc≤U
i
≤28Vdc;I
i
= 100mA; P
i
= 700mW; C
i
= 2,2nF; L
i
= 0mH
Ex-Designation
Transmitter without display Ex ia IIC T4 Ga / Ex ia IIIC T131°C Da
Transmitter with display Ex ia IIC T4 Gb / Ex ia IIB T4 Ga
Remote sensing probe Ex ia IIC T6-T1 Ga / Ex ia IIIC T80°C Da
Humidity and temperature probe:
• T6temperatureclassbasedon-40°C(-40°F)≤Ta≤60°C(140°F)
• T5temperatureclassbasedon-40°C(-40°F)≤Ta≤75°C(167°F)
• T4temperatureclassbasedon-40°C(-40°F)≤Ta≤110°C(230°F)
• T3temperatureclassbasedon-40°C(-40°F)≤Ta≤175°C(347°F)
• T2temperatureclassbasedon-40°C(-40°F)≤Ta≤180°C(356°F)
• T1temperatureclassbasedon-40°C(-40°F)≤Ta≤180°C(356°F)
Temperature probe:
• T6temperatureclassbasedon-70°C(-94°F)≤Ta≤60°C(140°F)
• T5temperatureclassbasedon-70°C(-94°F)≤Ta≤75°C(167°F)
• T4temperatureclassbasedon-70°C(-94°F)≤Ta≤110°C(230°F)
• T3temperatureclassbasedon-70°C(-94°F)≤Ta≤175°C(347°F)
• T2temperatureclassbasedon-70°C(-94°F)≤Ta≤200°C(392°F)
• T1temperatureclassbasedon-70°C(-94°F)≤Ta≤200°C(392°F)
TKG TKD
Humidity and
Temperature Probe
TKG TKD Temperature Probe
T6 80°C
-40°C≤ Tamb ≤+60°C
T6 80°C
-70°C≤ Tamb ≤+60°C
T5 95°C
-40°C≤ Tamb ≤+75°C
T5 95°C
-70°C≤ Tamb ≤+75°C
T4 130°C
-40°C≤ Tamb ≤+110°C
T4 130°C
-70°C≤ Tamb ≤+110°C
T3 195°C
-40°C≤ Tamb ≤+175°C
T3 195°C
-70°C≤ Tamb ≤+175°C
T2 200°C
-40°C≤ Tamb ≤+180°C
T2 220°C
-70°C≤ Tamb ≤+200°C
T1 200°C
-40°C≤ Tamb ≤+180°C
T1 220°C
-70°C≤ Tamb ≤+200°C