Operating instructions
28
8. TECHNICAL DATA - EE300EX-xT
Measuring values
Temperature
Temperature sensor Pt1000 (Tolerance class A, DIN EN 60751)
Measuring range sensor head wall mounting: -40...60°C (-40...140°F)
remote sensing probe: -70...200°C (-94...392°F)
Accuracy
1)
Temperature dependence of electronics typ. 0.005 °C/°C
Outputs
Scaleable analogue output 4 - 20 mA (2-wire) R
L
=(Vcc-9V)/20mA
General
Supply voltage (Class III) V
cc min
=(9+R
L
*0.02)VDC V
cc max
=28VDC
Current consumption max 20mA
Pressure range for pressure tight sensor probe 0.1 ... 20bar (1.5...300psi)
Serial interface for communication
2)
RS232
System requirements for software WINDOWS XP or later
Protection class of housing IP65; NEMA 4
Cable gland M16 for cable diameter 5 - 10 mm (0.2 - 0.4“)
Electrical connection screw terminals max. 1.5 mm² (AWG 16)
Temperature range sensor head according measuring range
electronic -40...60°C (-40...140°F)
electronic with display -20...60°C (-4...140°F)
Storage temperature range electronic and sensor head -20...60°C (22...140°F)
Electromagnetic compatibility according EN61326-1 EN61326-2-3 ICES-003 ClassB
Industrial Environment FCC Part15 ClassB
Material housing stainless steel 1.4404
probe cable PTFE
temperature probe stainless steel 1.4541
1) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation).
The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) Configuration adapter EE-PCA and cabel HA011061 necessary.
∆°C
°C